Description
Fluke 4695814 902FC True-RMS HVAC Clamp Meter
The Fluke 4695814 902FC True-RMS HVAC Clamp Meter comes with:
- TL75 test leads (1 pair)
- 80BK integrated DMM temperature probe
- 2 – AA alkaline batteries
- Soft carrying case
- User’s manual
- Statement of calibration
Features:
- Model no. 902FC
- Item no. 4695814
- A wireless Fluke Connect®-enabled clamp meter
- Designed specifically for the needs of HVAC technicians
- Offers 200 µA DC current measurements to measure flame rod
- Extends resistance range to measure thermistors up to 60kΩ
- Captures flue gas temperature
- Measures start and run motor capacitors
- Measures variable frequency drive performance
- Ergonomic design fits in your hand and can be used while wearing personal protective equipment
- Large, easy-to-read backlit display improves readings in low light settings
- Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warranty
- Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
- Offers True-RMS voltage and current measurements to accurately measure non-linear signals
- Offers Min/Max recording to capture variations automatically
- Runs on two AA alkaline batteries
Measures:
- AC current to 600 A and AC and DC voltage to 600 V
- Capacitance to 1000 µF and DC current to 200 µA
- Temperature from -10 °C to 400 °C (14 °F to 752 °F)
- Resistance to 60 kΩ
Function |
||
A ac (via Jaw) | ||
Resolution | 0.01/0.1 A | |
Accuracy | 2.0% ±5 digit (45-65 Hz) | |
2.5% ±5 digit (65-400 Hz) | ||
Range | 60.00/600.0 A | |
Crest Factor (50Hz or 60Hz) | 2.5 MIN@220 A 3.0 MIN@180 A > 1.4 MIN@600 A Add 2% for CF>400 A |
|
V ac | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
V dc | ||
Resolution | 0.1 V | |
Accuracy | 1.5% ±5 digits | |
Range | 600.0 V | |
Ohms | ||
Resolution | 0.1/1/10 | |
Accuracy | 1% ±5 digits | |
Range | 600/6000/60.00 kΩ | |
Capacitance | ||
Resolution | 0.1/1 µF | |
Accuracy | 1% ±4 digits | |
Range | 100.0/1000 µF | |
µA | ||
Resolution | 0.1 µA | |
Accuracy | 1% ±5 digits | |
Range | 200 µA | |
Contact temperature | ||
Resolution | 0.1 C/F | |
Accuracy | 1% ±8 digits | |
Range | -40 to 400 °C (-40 °F to 752 °F) | |
Continuity beeper | ||
Beeper volume | 75 dBA nom. 15 cm. from case front | |
On threshold | <=30 Ω | |
Mechanical and General Specifications |
||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 2 AA alkaline batteries, NEDA 15A, IEC LR6 | |
Temperature | Operating: -10 °C to +50 °C (14 °F to +122 °F) Storage: -40 °C to +60 °C (-40 °F to +140 °F) |
|
Operating humidity | Non condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F)) | |
Altitude | Operating: 3,000 m (9,842 ft) Storage: 12,000 m (39,370 ft) |
|
Dimensions | 230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in) | |
Weight (meter only) | 419 g (15 oz) | |
Safety | IEC 61010-1, Pollution Degree 2 IEC61010-2-032: CAT III 1000 V / CAT IV 600 V IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V |
|
IP Rating | IEC 60529: IP30, non-operating | |
Radio Frequency Certification | FCC ID:T68-FBLE IC:6627A-FBLE | |
Electromagnetic Compatibility (EMC) | International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |
Temperature coefficients | Add 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C |