Fluke 2538803 116 Digital HVAC Multimeter

Sale!

$310.00

Model no. 116

Only 2 Available (can be backordered)

UOM: EA SKU: 2538803 Categories: , , Tag: UPC: 095969324199

Description

Fluke 2538803 116 Digital HVAC Multimeter

The Fluke 2538803 116 Digital HVAC Multimeter comes with:

  • 4 mm silicone test lead set
  • 80BK Integrated Temperature probe
  • Holster
  • Installed 9 V battery
  • User manual

Features:

  • Model no. 116
  • Item no. 2538803
  • Digital multimeter designed specifically for HVAC professionals
  • Built-in thermometer to measure temperature from -40°C to 400°C (-40°F to 752°F)
  • Provides microamps to test flame sensors
  • Low input impedance to helps prevent false readings due to ghost voltage
  • Large white LED backlight for working in poorly lit areas
  • Provides Min/Max/Average to record signal fluctuations
  • Comes with a holster with probe holders for easy storage
  • Features a compact ergonomic design for one-handed operation
  • Fits into optional ToolPak™ magnetic hanger for hands-free operation
  • CAT III 600 V safety rated

Measures:

  • Resistance
  • Continuity
  • Frequency
  • Capacitance
Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2
Display Digital: 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating temperature -10°C to + 50°C
Storage temperature -40°C to + 60°C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life 400 hours typical, without backlight
Accuracy Specifications
DC millivolts Range/resolution 600.0 mV / 0.1 mV
Accuracy ±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy ±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution 600.0 V / 0.1 V
Accuracy 2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts1 True RMS Range/resolution 600.0 mV / 0.1 mV
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts1 True RMS Range/resolution 6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy 1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution 600 Ω / 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of
500 μs or longer.
Ohms Range/resolution 600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy 0.9% + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 5% + 2
Diode Test Range/resolution 2.00 V / 0.001 V
Accuracy 0.9% + 2
Capacitance
Range/resolution 1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy 1.9% + 2
Range/resolution > 1000 μF
Accuracy 5% + 20%
Lo-Z Capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature²
(Type-K thermocouple)
Range/resolution -40°C to 400°C / 0.1°C
Accuracy 1% + 10²
Range/resolution -40°F to 752°F / 0.2°F
Accuracy 1% + 18²
AC μA true-rms (45 Hz to 500 Hz) Range/resolution 600.0 μA / 0.1 μA
Accuracy 1.5% + 3
DC μamps Range/resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight 550 g
Warranty 3 years

Additional information

Weight 5 lbs
Brand Name