Fluke 2074974 87V Industrial Multimeter

$720.79

Model no. 87V

Backorder

UOM: EA SKU: 2074974 Categories: , , UPC: 095969245241

Description

Fluke 2074974 87V Industrial Multimeter

The Fluke 2074974 87V Industrial Multimeter comes with:

  • TL75 Test Leads
  • AC175 Alligator Clips
  • Holster
  • 9V Battery (Installed)
  • 80BK Temperature Probe

Features:

  • Model no. 87V
  • Item no. 2074974
  • Rugged, high accuracy industrial multimeter
  • Measure current, voltage and frequency on complex variable frequency drive (VFD) signals
  • Offers true-RMS AC voltage and current for measuring non-linear signals
  • Captures intermittents as short as 250 µS
  • Safety rated CAT III 1000V, CAT IV 600V
  • Includes a built-in thermometer and temperature probe
  • Easy access door for fast battery changes without breaking the calibration seal
  • Removable holster with built in test lead and probe storage for convenience
  • Audible Input Alert warning against wrong use of input jacks
  • Provides peak capture and Min/Max/Avg recording to capture intermittents as short as 250 µS
  • Designed and built in the U.S.
  • Comes with a lifetime warranty
  • Features—6000 counts, 3-3/4 digit resolution, or 20,000 counts, 4-1/2 digit—resolution
  • Fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
  • Includes an analog barograph for fast changing or unstable signals
  • Presents a large digit display with bright, two-level backlight for easier reading in low light
  • Delivers 0.05% DC accuracy
  • Measures up to 1000V AC and DC
  • Provides 10,000 µF capacitance range for components and motor caps
  • Offers relative mode to remove test lead interference from low ohms measurements
  • Features auto and manual ranging for maximum flexibility
  • Includes Touch Hold to capture stable readings of noisy signals
Specifications
Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per khz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20 °C to + 55 °C
Storage temperature –40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals UL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display
Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument

Additional information

Weight 5 lbs
Brand Name

Instruments

Electrical Testers and Meters

Reviews

There are no reviews yet.

Be the first to review “Fluke 2074974 87V Industrial Multimeter”